Diesel heater: white smoke and no start

Updated

Heavy white smoke with no ignition means fuel is reaching the burner but not lighting. Owners traced it to a clogged glow plug screen, a burn chamber packed with carbon, flooding from repeated priming, a fuel-filled exhaust and a failed or under-powered glow plug. Stop restarting and stop priming first: each attempt adds more fuel.

Which controller do you have?

The same number means different faults on different controllers. Match yours to a sketch first. The symptom is the same on every controller, but the code that follows it differs: check the table for your panel.

Not sure? Use the full controller guide

At a glance

What is happeningFuel is arriving at the burner but is not igniting
Most common causeCarbon on the glow plug screen or in the burn chamber; flooding after repeated priming; fuel in the exhaust
Check this firstStop priming and restarting, then check the exhaust for fuel or water
EvidenceManuals and owner reports

Codes by controller

CodeControllerManual or brandMeaningStated limit
E-085-button LCDOnTrack Outdoor 5 kW
Manual
Flame failure
Manual's remedy: Check whether the fuel circuit is blocked (poor fuel supply); check tank is clean and has fuel; check fuel filter; try a higher setting (higher pump speed); if all checked and there is smoke, replace the glow plug.
Not stated
E-085-button LCDD2/D4 parking heater (generic manual)
Manual
Flame-out ('fray-out of flame')
Manual's remedy: Check whether the fuel line has air in it or is obstructed.
Not stated
E-085-button LCDHcalory M98
Manual
Extinguished (flame-out)
Manual's remedy: Tank short of fuel, pump abnormal or fuel quality problem; fuel circuit leaking or with bubbles so supply is not continuous; intake and exhaust pipes blocked.
Not stated
E-105-button LCDOnTrack Outdoor 5 kW
Manual
Ignition failure
Manual's remedy: Check whether the fuel circuit is blocked and fuel quality; check fan moves freely; glow plug cables; clean or replace the filter (screen) at the glow plug; check combustion intake and exhaust are clear; check power connections for oxidation.
Not stated
E-105-button LCDD2/D4 parking heater (generic manual)
Manual
Ignition failure
Manual's remedy: Check for air or obstruction in the fuel line; fuel line blocked or not flowing; poor diesel quality blocking the 'volatile network' (burner screen).
Not stated
E-105-button LCDHcalory M98
Manual
Ignition failure - failed to start after trying twice ('both sides'), failed to form a flame
Manual's remedy: Check whether the tank is short of fuel; pump stuck or abnormal; fuel circuit correct and free of bubbles; poor power supply or fuel problem.
Two start attempts
E-08Vevor M-button panelVevor XMZ-D1 / XMZ-D2
Manual
Flame out due to lack of oil (fuel)
Manual's remedy: Check the fuel tank for lack of fuel.
Not stated
E-10Vevor M-button panelVevor XMZ-D1 / XMZ-D2
Manual
Secondary startup failed
Manual's remedy: Check whether the fuel pump works; check whether the fuel circuit fittings are waxed up or blocked.
Not stated
E-8LCD, E-2 … E-10Vevor CY-5001/5002/5004, 5-key and 3-key LCD panels
Manual
Flame-out (printed 'Turn off the engine')
Manual's remedy: Check for fuel shortage, fuel gelled by cold, blocked fuel circuit, stuck pump; check combustion air intake and exhaust are unobstructed; check the casing temperature sensor is in full contact with the casing and its spring is strong.
Not stated
E-8LCD, E-2 … E-10Gasmate DH203
Manual
Fail to start (first of two causes listed under E-8)
Manual's remedy: Check power source capacity (will not start from a regular car cigarette socket or an outlet under 15 A); fuel level; fuel condition (drain old fuel); winter/alpine diesel at low temperature; combustion intake and exhaust openings; otherwise service.
Power source must supply at least 15 A
E-8LCD, E-2 … E-10Gasmate DH203
Manual
Flameout (second cause listed under E-8)
Manual's remedy: If recently used the heat exchanger may be too hot - let it cool fully and retry; lots of white smoke on start: service glow plug, screen and fuel pump; little or no white smoke: check intake/exhaust openings, fuel level, fuel condition, winter diesel; temperature sensor service.
Not stated
E-08LCD, E-2 … E-10Liwolf all-in-one
Manual
Stall (flame-out); printed as E-08 in a table that otherwise uses E-2 to E-9
Manual's remedy: Check for low fuel, fuel gelled by cold, fuel pipe blockage or pump jamming; intake and exhaust airflow paths clear; housing temperature sensor in good contact with the housing.
Not stated
E-8LCD, E-2 … E-10Liwolf all-in-one
Manual
Start failure; printed as E-8 (the same table also has the E-08 stall row)
Manual's remedy: 1) Housing too hot and cooling fails: wait until cooled and power on again. 2) Excess white smoke: check filter next to the ignition plug, pump injection, ignition plug. 3) Little or no white smoke: fuel shortage, frozen/blocked fuel pipe, pump stuck, intake/exhaust blockage, ignition plug, internal fan-wheel gap. 4) Ignition normal but fault persists: housing temperature sensor contact.
Not stated
E-10LCD, E-2 … E-10Vevor CY-5001/5002/5004, 5-key and 3-key LCD panels
Manual
Unsuccessful startup
Manual's remedy: 1) Casing too hot and not cooled after 3 minutes of start-up. 2) Lots of white smoke in exhaust: check the filter screen next to the ignition plug (clean/replace), whether the pump sprays fuel forcefully, whether the ignition plug is aged. 3) Little or no white smoke: check for fuel shortage, frozen or blocked fuel circuit, pump stuck/damaged, combustion intake and exhaust clear, ignition plug damaged, inner fan-wheel clearance too large. 4) Ignites normally but still reports ignition failure: check the casing temperature sensor is in full contact with the casing, its pressure spring, and the sensor itself.
Casing not cooled after 3 minutes of start-up (cause 1)
E8Rotary-switch LCD, E0 … E15Heatport H2 / H4 (EnControl)
Manual
Blower motor
Manual's remedy: Check heating air intake for obstructions and that the blower turns freely; impeller damage (obstruction, over-torqued ducting clamp, debris under the heater) - replace blower; short circuit - check resistance and wiring; loose ECU casing / mispositioned magnetic sensor - fix ECU position; ECU.
Speed failure: motor speed off specification by more than 10% for longer than 30 seconds
E8Rotary-switch LCD, E0 … E15T4 two-knob LCD switch
Manual
Motor
Manual's remedy: Fix/reinstall the fan blade if stuck; replace the motor if defective; check the Hall sensor or circuit board; ensure motor wires are connected to the board socket.
Not stated
E10Rotary-switch LCD, E0 … E15Heatport H2 / H4 (EnControl)
Manual
Overheat: excess temperature measured at the overheat sensor
Manual's remedy: Check fan not blocked/damaged; check ducting free from obstruction; remove the PT1000 sensor, check connections/wiring and reinstall; replace sensor if wiring damaged; ECU.
Not stated
E10Rotary-switch LCD, E0 … E15T4 two-knob LCD switch
Manual
Overheat
Manual's remedy: Verify the air duct is not blocked; address temperature sensor failure or loose contact with the aluminium heat exchanger ('radiator').
Not stated
E-08Knob LCD (Hcalory HC-A01)Hcalory HC-A01
Manual
Ignition plug abnormality
Manual's remedy: Check the ignition plug connection; faulty plug - replace; main board failure - replace.
Not stated
E-10Knob LCD (Hcalory HC-A01)Hcalory HC-A01
Manual
Furnace temperature sensor abnormal
Manual's remedy: Check the furnace temperature sensor connector for a loose connection; incorrect or faulty sensor type - replace; main board failure - replace.
Not stated
E-08B2010 (spanner button)B2010 controller
Manual
Flame failure
Manual's remedy: Check for air or wax blockage in the fuel circuit causing poor fuel supply.
Not stated
E-10B2010 (spanner button)B2010 controller
Manual
Ignition failure (after two failed ignition attempts)
Manual's remedy: Check for blocked fuel circuit, poor fuel intake, stuck fuel pump, or blocked 'volatile net' (burner screen) due to fuel problems.
Two failed ignitions

Why does my heater blow white smoke and not start?

The Vevor CY manual uses the smoke to split a failed start in two. Manual

  • Lots of white smoke: fuel is arriving. The manual sends you to the filter screen next to the ignition plug, to whether the pump sprays fuel forcefully, and to an aged ignition plug. Manual
  • Little or no white smoke: fuel is not arriving. The manual lists fuel shortage, a frozen or blocked fuel circuit and a stuck pump. Manual For that case see tries to start, then E-10.

The same manual says white smoke that appears after a period of running means the atomising screen is clogged, and that over-priming causes heavy white smoke. Manual

The heater usually gives up with a flame-out or failed-start code. Which number that is depends on the controller: see the table above.

What did owners actually find?

Each line counts different owners who reported both the cause and what fixed it. Reports seen only as search excerpts are not counted, and neither is an owner who changed several things at once.

Cause found and fixed Owners
Glow plug screen or plug well clogged with carbon 2
Burn chamber packed with carbon 2
Burner flooded by repeated priming 2
Exhaust holding unburnt fuel 2
Glow plug burnt out or under-powered 2
Burn chamber burnt out inside, replaced 1
Exhaust longer than supplied 1

All counts are from owner reports. Owners No single cause reaches three owners, so read the table as a list of places to look, not as a ranking.

Two more owners named a cause without describing a fix: one has had E10 with flooding from a clogged ignition screen, and one gets white smoke and E10 when rain has blown into the exhaust. Owners

Notes on these cases:

  • One owner clogged a new heater’s chamber with runs of 15 to 20 minutes at low heat. Owners
  • One owner whose heater only smoked after months unused cured it by feeding the heater straight from the battery and cleaning dirty fuel out of the tank. Owners
  • One owner’s exhaust was blocked by excess sealant and ran uphill, so it filled with fuel. Owners

What should I check, and in what order?

  1. Stop. Do not keep restarting and do not prime again. Two owners flooded the burner by priming again and again. Owners
  2. Check the supply during the start. The OnTrack guide says the battery should not drop below 12 V during start-up, and that the voltage across the glow plug should rise slowly to 8 to 9 V. Manual If the battery sags, fix the supply first. One owner cured a smoke-only heater by feeding it straight from the battery. Owners
  3. Check the exhaust. With the heater off and cold, take the exhaust pipe off and tip it out. Fuel or water in it means it was blocking the flow. Refit it with a continuous fall so liquid drains out, as the owner with the uphill pipe did. Owners If the pipe has been extended, go back to the supplied length: one camper converter’s heater would not light with a longer exhaust and lit with the standard one. Owners
  4. Look at the fuel. After long storage, drain old or dirty fuel, as one owner had to. Owners In freezing weather check that the fuel has not gelled: the Vevor CY manual lists fuel gelled by cold under flame-out. Manual
  5. Service the glow plug and its screen. Two owners got a smoke-only heater running by cleaning the screen or the plug well. Owners The OnTrack guide gives 0.6 to 0.8 ohm as the reading for a good glow plug, and says that if the fuel side has been checked and there is smoke, replace the plug. Manual Steps are in cleaning the glow plug and its screen.
  6. Deal with a flooded burner. The Vevor CY manual’s method is to detach the fuel line, start the heater, let it stop by itself, and repeat until there is no smoke, then reconnect. Manual One owner instead removed the unit and drained the fuel out through the air intake. Owners Do this outdoors, with a container under the open fuel line. Keep the open line and the container well away from the exhaust: the pump still delivers fuel during the dry run and the exhaust gets hot.
  7. Carbon in the burn chamber. If the plug and screen are clean and the exhaust is clear, the chamber is the next suspect. Clearing it means opening the heater and fitting new gaskets.
Plug lead (to harness)Plug topglow plugmesh screenlines the wellburnerThe glow plug sits in a well lined with a fine mesh screen.Owners find this screen gummed or coked up on hard-starting heaters.
The glow plug sits in a well lined with a fine mesh screen, which owners find gummed or coked up on hard-starting heaters. Schematic drawing, not to scale.

If you are not sure, ask a technician. Opening the combustion chamber goes beyond routine owner maintenance. A mistake here can cause a fuel or exhaust leak. Stop if anything is unclear.

It started. Why is it still smoking?

The fuel left by the failed starts has to burn off. The Belief manual says to run the heater for 20 to 25 minutes to see if the smoke clears, and that smoke continuing after 25 minutes with the inlet and exhaust clear means it needs a service. Manual Dieselheat’s guide gives a similar test: if it is still smoking after 15 minutes on full power, with the air inlet and exhaust checked for partial blockage, it needs a service. Manual

One owner who had over-primed reports the heater cleared after a clean-out and two 10-minute runs on high. Owners

How do I clear the code afterwards?

Fix the cause first, then reset. What each manual says about resetting is on how to reset a locked-out heater. When you next need to fill the line, follow manual fuel priming and stop as soon as fuel reaches the heater: over-priming is what floods the burner.

When should I stop and call a technician?

  • The heater still smokes after the run times above.
  • The plug, screen and exhaust are all clean and it will not light.
  • The chamber is damaged inside. One owner’s heater needed a new burn chamber. Owners
  • The glow plug gets too little voltage although the supply at the heater is good. One owner measured that and suspected the control board, without confirming it. Owners

Related questions

Is white smoke on start-up always a fault?
Not always. After failed starts the heater burns off the fuel they left behind: the Belief manual says to run it 20 to 25 minutes to see whether the smoke clears. Smoke with no ignition at all, or smoke that never clears, is a fault.
I replaced the glow plug and the screen and it still only smokes. What now?
One owner in that position found the burn chamber full of loose carbon, and emptying it fixed the heater. A second cleared the fault by cleaning carbon out of the chamber after a new pump and new lines had not helped. A third found the chamber burnt out inside and replaced it.
Can I burn off a flooded heater by just keeping it trying?
Each failed attempt pumps in more fuel. The Vevor CY manual's method for an over-primed heater is to detach the fuel line, start the heater and let it stop by itself, and repeat until there is no smoke before reconnecting.
Does white smoke mean the glow plug is dead?
Not necessarily. Two owners traced it to the glow plug, one burnt out and one starved of voltage by the supply wiring. Others found a clogged screen, carbon in the chamber or fuel in the exhaust instead.

Sources

Everything on this page is compiled from the documents and discussions below. We summarise them in our own words; follow the links for the originals.

  1. Vevor diesel heater manual, CY-5001 / CY-5002 / CY-5004 (PDF copy) (xlrzbfnheqpszgtyhdkh.supabase.co)
  2. Belief diesel air heater user guide, rotary control (PDF) (dieselheat.com.au)
  3. Dieselheat: diesel air heater fault finding guide (PDF) (dieselheat.com.au)
  4. OnTrack Outdoor: diesel heater troubleshooting guide (PDF) (cdn.shopify.com)
  5. Owner report: E10 and flooding from a clogged ignition screen, no fix described (Reddit r/dieselheater) (reddit.com)
  6. Owner report: E-10 with smoke cured by cleaning the plug screen, later the burner (drive2.ru) (drive2.ru)
  7. Owner report: smoke and no heat, deposits wiped from the glow plug bore (drive2.ru) (drive2.ru)
  8. Owner report: E-08 cleared by cleaning carbon out of the chamber (Reddit r/dieselheater) (reddit.com)
  9. Owner report: chamber full of loose carbon after short low-heat runs (Reddit r/vandwellers) (reddit.com)
  10. Owner report: several changes at once, carbon burnt out of chamber and exhaust, cause not isolated (Reddit r/dieselheater) (reddit.com)
  11. Owner report: burn chamber destroyed inside, replaced (Reddit r/dieselheater) (reddit.com)
  12. Owner report: burner flooded after priming 5 to 7 times (Reddit r/vandwellers) (reddit.com)
  13. Owner report: over-primed heater, diesel inside the unit (Reddit r/dieselheater) (reddit.com)
  14. Owner report: exhaust blocked by sealant and angled upward (Reddit r/dieselheater) (reddit.com)
  15. Owner report: exhaust pipe flooded with unburnt fuel (Reddit r/VanLife) (reddit.com)
  16. Owner report: white smoke and E10 after rain blew into the exhaust, no fix described (Reddit r/dieselheater) (reddit.com)
  17. Owner report: no ignition and white smoke with a longer exhaust (PistonHeads forum) (pistonheads.com)
  18. Owner report: white smoke after months unused, glow plug under-powered (The Grey Nomads forum) (thegreynomads.activeboard.com)
  19. Owner report: low voltage at the glow plug with a good supply, board suspected (The Grey Nomads forum) (thegreynomads.activeboard.com)
  20. Owner report: same symptom from a burnt-out glow plug (The Grey Nomads forum) (thegreynomads.activeboard.com)