Heater tries to start for minutes, then shows E-10
Updated
E-10 after several minutes of trying means the heater made two start attempts and neither lit. Dieselheat's guide gives three likely causes: no fuel, insufficient power, or no air flow. Start by watching the fuel line while the pump ticks: fuel has to move towards the heater.
Which controller do you have?
The same number means different faults on different controllers. Match yours to a sketch first. E-10 means a failed start on the 5-button LCD, the B2010 and the Vevor M-button panel; other panels use a different code for the same event.
- 5-button LCDE-01 … E-10 with two digits, on a black panel with five round buttonsThis page applies
- Vevor M-button panelE-xx flashing on a colour screen, four keys including M, voice promptsThis page applies
- Rotary knob, LEDsNo screen: an LED flashes a count, pauses, repeats
- LCD, E-2 … E-10E-2 … E-10, one digit after the dash, no E-1
- Rotary-switch LCD, E0 … E15E1, E2, E3 … with no dash, on an LCD switch you turn and press
- Knob LCD (Hcalory HC-A01)E-01 … E-10 on a colour LCD with one push-turn knob
At a glance
| Code | E-10 |
|---|---|
| Meaning | Two start attempts failed and the heater locked out |
| Most common cause | Fuel not reaching the burner: empty line, pickup out of the fuel, or a pump that ticks without pumping |
| Check this first | Watch the fuel line while the pump ticks: does fuel move towards the heater? |
| Evidence | Manuals and owner reports |
What E-10 means on each controller
| Code | Controller | Manual or brand | Meaning | Stated limit |
|---|---|---|---|---|
| E-10 | 5-button LCD | OnTrack Outdoor 5 kW Manual | Ignition failure Manual's remedy: Check whether the fuel circuit is blocked and fuel quality; check fan moves freely; glow plug cables; clean or replace the filter (screen) at the glow plug; check combustion intake and exhaust are clear; check power connections for oxidation. | Not stated |
| E-10 | 5-button LCD | D2/D4 parking heater (generic manual) Manual | Ignition failure Manual's remedy: Check for air or obstruction in the fuel line; fuel line blocked or not flowing; poor diesel quality blocking the 'volatile network' (burner screen). | Not stated |
| E-10 | 5-button LCD | Hcalory M98 Manual | Ignition failure - failed to start after trying twice ('both sides'), failed to form a flame Manual's remedy: Check whether the tank is short of fuel; pump stuck or abnormal; fuel circuit correct and free of bubbles; poor power supply or fuel problem. | Two start attempts |
| E-10 | Vevor M-button panel | Vevor XMZ-D1 / XMZ-D2 Manual | Secondary startup failed Manual's remedy: Check whether the fuel pump works; check whether the fuel circuit fittings are waxed up or blocked. | Not stated |
| E-10 | LCD, E-2 … E-10 | Vevor CY-5001/5002/5004, 5-key and 3-key LCD panels Manual | Unsuccessful startup Manual's remedy: 1) Casing too hot and not cooled after 3 minutes of start-up. 2) Lots of white smoke in exhaust: check the filter screen next to the ignition plug (clean/replace), whether the pump sprays fuel forcefully, whether the ignition plug is aged. 3) Little or no white smoke: check for fuel shortage, frozen or blocked fuel circuit, pump stuck/damaged, combustion intake and exhaust clear, ignition plug damaged, inner fan-wheel clearance too large. 4) Ignites normally but still reports ignition failure: check the casing temperature sensor is in full contact with the casing, its pressure spring, and the sensor itself. | Casing not cooled after 3 minutes of start-up (cause 1) |
| E10 | Rotary-switch LCD, E0 … E15 | Heatport H2 / H4 (EnControl) Manual | Overheat: excess temperature measured at the overheat sensor Manual's remedy: Check fan not blocked/damaged; check ducting free from obstruction; remove the PT1000 sensor, check connections/wiring and reinstall; replace sensor if wiring damaged; ECU. | Not stated |
| E10 | Rotary-switch LCD, E0 … E15 | T4 two-knob LCD switch Manual | Overheat Manual's remedy: Verify the air duct is not blocked; address temperature sensor failure or loose contact with the aluminium heat exchanger ('radiator'). | Not stated |
| E-10 | Knob LCD (Hcalory HC-A01) | Hcalory HC-A01 Manual | Furnace temperature sensor abnormal Manual's remedy: Check the furnace temperature sensor connector for a loose connection; incorrect or faulty sensor type - replace; main board failure - replace. | Not stated |
| E-10 | B2010 (spanner button) | B2010 controller Manual | Ignition failure (after two failed ignition attempts) Manual's remedy: Check for blocked fuel circuit, poor fuel intake, stuck fuel pump, or blocked 'volatile net' (burner screen) due to fuel problems. | Two failed ignitions |
Why does my heater try to start for minutes and then show E-10?
The heater tries to light, fails, tries once more and then gives up. Dieselheat’s guide says the whole cycle takes about 6 minutes for the 2 attempts, then the heater locks out with E10. Manual The B2010 manual and the Hcalory M98 manual both define E-10 as two failed ignition attempts, and the Vevor XMZ manual calls it a failed secondary start-up. Manual
Dieselheat names three likely causes: no fuel, insufficient power, or no air flow. Manual The other manuals mostly point at fuel:
- B2010: blocked fuel circuit, poor fuel intake, stuck fuel pump, or a blocked burner screen. Manual
- Vevor XMZ: check that the fuel pump works and that the fuel fittings are not waxed up or blocked. Manual
- Hcalory M98: tank short of fuel, pump stuck, bubbles in the fuel circuit, poor power supply or a fuel problem. Manual
- OnTrack: adds the screen at the glow plug, a fan that does not move freely, blocked combustion intake or exhaust, and oxidised power connections. Manual
Which causes did owners actually confirm?
Counts are owners who reported E-10, the cause and the fix, in threads that were read in full. Owners
| Cause | Owners |
|---|---|
| Fuel not delivered: pump ticks but does not pump (3), pump fitted backwards (1), pickup out of the fuel (1) | 5 |
| Combustion air or exhaust blocked, a different blockage each time | 2 |
| Glow plug screen clogged with carbon | 1 |
| Burn chamber burnt out inside | 1 |
| Low voltage at start in extreme cold | 1 |
| Pump setting too low in the advanced menu | 1 |
Fuel delivery leads, which matches the manuals. The two air cases were a clogged add-on intake filter in hard frost and an exhaust longer than the one supplied; that owner recalled the code as E-10 from memory. Owners
Three more reports are left out of the counts. One owner gets white smoke and E10 when rain has blown water into the exhaust, and one has had E10 with flooding from a clogged glow plug screen; neither describes a fix. Owners A third, a gummed screen after a week of running, was seen only as a search excerpt.
What should I check first?
Work from the tank towards the heater, then power, then air.
- Fuel in the tank, pickup in the fuel. One owner’s heater showed E-10 in the night because the pickup line was no longer submerged. Owners Dieselheat adds that the tank must not be more than 2 m (6.6 ft) below the pump. Manual
- Watch the line while the pump ticks. Fuel should move towards the heater. In one confirmed case the air bubble in the line only shuffled back and forth, and a new pump cured it. Owners If the line is simply empty after an install or a dry tank, go to step 4.
- Measure what the pump delivers. Dieselheat’s test: disconnect the fuel line at the heater, switch on, and catch the output. Each tick should deliver about a quarter of a teaspoon of diesel. Manual Ticking with nothing coming out means a blockage or a dead pump. On an unmarked replacement pump, check the direction: inlet from the tank, outlet to the heater. Owners
- Fill an empty line. Use the controller’s priming routine, described in manual fuel priming, and stop as soon as fuel reaches the heater. Over-priming floods the burner. The Vevor M-button panel’s routine is a fixed 300 s countdown that ends by itself or when you press power. Manual Dieselheat’s alternative is repeated start cycles, up to 6 on a new or run-dry heater. Manual
- Power. Dieselheat says to connect directly to the battery with the supplied loom, and if it has to be extended, to use 6 mm² wire with soldered joins. Manual The OnTrack guide says the battery should not drop below 12 V during start-up. Manual One owner in extreme cold got E10 from low voltage at start and simply retried until it lit. Owners
- Air. Check the combustion air intake for a clogged filter and the exhaust for water or a blockage. If the exhaust has been extended, go back to the supplied length. Each of these was reported with E-10 by one owner. Owners
- Glow plug screen. For a failed start with lots of white smoke, the Vevor CY manual says to check the screen next to the glow plug, and the OnTrack guide lists cleaning or replacing that screen under E-10. Manual See cleaning the glow plug and its screen and white smoke and no start.
Could the pump setting be the cause?
One owner reports E-10 kept appearing until the fuel pump setting was raised in the advanced menu. Owners That is a single report, and it only applies to controllers with a tuning menu. The Vevor XMZ manual describes none.
Before changing any pump or fan value
Details are on the hidden settings menu.
How do I clear E-10 after the fix?
Dieselheat’s guide resets its heaters by removing and refitting the fuse near the battery. Manual The B2010, Hcalory M98 and Vevor XMZ manuals print no reset step. If you do disconnect power, wait until the heater has finished its cool-down: the Vevor XMZ manual says it needs 3 to 5 minutes to stop completely. Manual See how to reset a locked-out heater, and do not keep resetting without a fix: each failed attempt leaves unburnt fuel in the burner.
When is it time to stop?
If fuel reaches the heater at the right rate, the supply holds up, the air paths are clear and the screen is clean, the cause is inside the burner. One owner with E-10 and smoke after long use found the burn chamber destroyed inside, and a new chamber fixed it. Owners A fuel dosing pump that ticks without pumping is a replacement part, not a repair.
If you are not sure, ask a technician. Opening the combustion chamber goes beyond routine owner maintenance. A mistake here can cause a fuel or exhaust leak. Stop if anything is unclear.
Related questions
- How long does the heater try before it shows E-10?
- Dieselheat's guide says the start cycle takes about 6 minutes for 2 attempts, then the heater locks out. The B2010 and Hcalory M98 manuals also define E-10 as two failed attempts, without giving a time.
- The pump is clicking, so why is there no fuel?
- A clicking pump is not proof of flow. Three owners had pumps that ticked normally but delivered nothing, and a new pump cured each one. A fourth had fitted an unmarked replacement pump backwards.
- It is a new install. Is E-10 normal on the first start?
- It can be. Dieselheat says a new or run-dry heater can need up to 6 complete start cycles to purge the fuel line. Using the controller's priming routine fills the line without start attempts, but stop as soon as fuel reaches the heater.
- There is smoke while it tries to start. Does that change anything?
- Yes. The Vevor CY manual splits a failed start that way: lots of white smoke points to the screen next to the glow plug, the pump's spray and an aged plug, while little or no smoke points to the fuel supply. Owners with smoke and E-10 also found a burnt-out burn chamber and a blocked air path.
Where to go next
Sources
Everything on this page is compiled from the documents and discussions below. We summarise them in our own words; follow the links for the originals.
- Dieselheat: diesel air heater fault finding guide (PDF) (dieselheat.com.au)
- B2010 controller operating manual V1.2 (PDF) (cdn.shopify.com)
- Vevor diesel heater manual, XMZ-D1 / XMZ-D2 (PDF copy) (tuitam.pl)
- Hcalory air heater user manual, M98 (PDF) (cdn.shopify.com)
- OnTrack Outdoor: diesel heater troubleshooting guide (PDF) (cdn.shopify.com)
- Vevor diesel heater manual, CY-5001 / CY-5002 / CY-5004 (PDF copy) (xlrzbfnheqpszgtyhdkh.supabase.co)
- Owner report: E-10 with pump ticking but not delivering, spare pump fitted (drive2.ru) (drive2.ru)
- Owner reports: constant E-10, air bubble only moved back and forth, new pump (drive2.ru) (drive2.ru)
- Owner report: E10 from a replacement pump fitted backwards (motorhomer.com forum) (motorhomer.com)
- Owner report: E-10 because the fuel pickup was not submerged (Expedition Portal forum) (forum.expeditionportal.com)
- Owner reports: E-10 with smoke, plug screen and burner cleaned; intake filter removed (drive2.ru) (drive2.ru)
- Owner post, search excerpt only: E10 after a week, glow plug screen gummed (Reddit r/dieselheater) (reddit.com)
- Owner report, no fix described: E10 and flooding from a clogged ignition screen (Reddit r/dieselheater) (reddit.com)
- Owner report: E-10 and smoke, burn chamber destroyed inside (Reddit r/dieselheater) (reddit.com)
- Owner report: no ignition with an extended exhaust (PistonHeads forum) (pistonheads.com)
- Owner report, no fix described: white smoke and E10 after rain blew into the exhaust (Reddit r/dieselheater) (reddit.com)
- Owner report: E10 from low voltage at start in extreme cold (Reddit r/dieselheater) (reddit.com)
- Owner report: E-10 until the pump setting was raised (Go Fast Campers forum) (forum.gofastcampers.com)