Diesel heater soot build-up and the high-power clean burn

Updated

Soot builds when the heater runs for long periods on a low setting, burns rich, or cannot breathe through its intake and exhaust. The usual prevention is a regular run at high power, but the documents give different intervals, so each is quoted below with its source. If the heater has already lost heat or will not start, a high-power run may not be enough and the burn chamber may need cleaning out.

Which controller do you have?

The same number means different faults on different controllers. Match yours to a sketch first. Soot affects every heater whatever its controller; the code a sooted heater ends on depends on the panel, so check the table for yours.

Not sure? Use the full controller guide

At a glance

What is happeningCarbon is collecting on the glow plug screen, in the burn chamber and in the exhaust
Most common causeLong hours on the lowest setting, a rich mixture, or a restricted intake or exhaust
Check this firstCheck the intake and exhaust are clear, then run at high power as your manual says
EvidenceManuals and owner reports

Codes by controller

CodeControllerManual or brandMeaningStated limit
E-085-button LCDOnTrack Outdoor 5 kW
Manual
Flame failure
Manual's remedy: Check whether the fuel circuit is blocked (poor fuel supply); check tank is clean and has fuel; check fuel filter; try a higher setting (higher pump speed); if all checked and there is smoke, replace the glow plug.
Not stated
E-085-button LCDD2/D4 parking heater (generic manual)
Manual
Flame-out ('fray-out of flame')
Manual's remedy: Check whether the fuel line has air in it or is obstructed.
Not stated
E-085-button LCDHcalory M98
Manual
Extinguished (flame-out)
Manual's remedy: Tank short of fuel, pump abnormal or fuel quality problem; fuel circuit leaking or with bubbles so supply is not continuous; intake and exhaust pipes blocked.
Not stated
E-105-button LCDOnTrack Outdoor 5 kW
Manual
Ignition failure
Manual's remedy: Check whether the fuel circuit is blocked and fuel quality; check fan moves freely; glow plug cables; clean or replace the filter (screen) at the glow plug; check combustion intake and exhaust are clear; check power connections for oxidation.
Not stated
E-105-button LCDD2/D4 parking heater (generic manual)
Manual
Ignition failure
Manual's remedy: Check for air or obstruction in the fuel line; fuel line blocked or not flowing; poor diesel quality blocking the 'volatile network' (burner screen).
Not stated
E-105-button LCDHcalory M98
Manual
Ignition failure - failed to start after trying twice ('both sides'), failed to form a flame
Manual's remedy: Check whether the tank is short of fuel; pump stuck or abnormal; fuel circuit correct and free of bubbles; poor power supply or fuel problem.
Two start attempts
E-08Vevor M-button panelVevor XMZ-D1 / XMZ-D2
Manual
Flame out due to lack of oil (fuel)
Manual's remedy: Check the fuel tank for lack of fuel.
Not stated
E-10Vevor M-button panelVevor XMZ-D1 / XMZ-D2
Manual
Secondary startup failed
Manual's remedy: Check whether the fuel pump works; check whether the fuel circuit fittings are waxed up or blocked.
Not stated
E-8LCD, E-2 … E-10Vevor CY-5001/5002/5004, 5-key and 3-key LCD panels
Manual
Flame-out (printed 'Turn off the engine')
Manual's remedy: Check for fuel shortage, fuel gelled by cold, blocked fuel circuit, stuck pump; check combustion air intake and exhaust are unobstructed; check the casing temperature sensor is in full contact with the casing and its spring is strong.
Not stated
E-8LCD, E-2 … E-10Gasmate DH203
Manual
Fail to start (first of two causes listed under E-8)
Manual's remedy: Check power source capacity (will not start from a regular car cigarette socket or an outlet under 15 A); fuel level; fuel condition (drain old fuel); winter/alpine diesel at low temperature; combustion intake and exhaust openings; otherwise service.
Power source must supply at least 15 A
E-8LCD, E-2 … E-10Gasmate DH203
Manual
Flameout (second cause listed under E-8)
Manual's remedy: If recently used the heat exchanger may be too hot - let it cool fully and retry; lots of white smoke on start: service glow plug, screen and fuel pump; little or no white smoke: check intake/exhaust openings, fuel level, fuel condition, winter diesel; temperature sensor service.
Not stated
E-08LCD, E-2 … E-10Liwolf all-in-one
Manual
Stall (flame-out); printed as E-08 in a table that otherwise uses E-2 to E-9
Manual's remedy: Check for low fuel, fuel gelled by cold, fuel pipe blockage or pump jamming; intake and exhaust airflow paths clear; housing temperature sensor in good contact with the housing.
Not stated
E-8LCD, E-2 … E-10Liwolf all-in-one
Manual
Start failure; printed as E-8 (the same table also has the E-08 stall row)
Manual's remedy: 1) Housing too hot and cooling fails: wait until cooled and power on again. 2) Excess white smoke: check filter next to the ignition plug, pump injection, ignition plug. 3) Little or no white smoke: fuel shortage, frozen/blocked fuel pipe, pump stuck, intake/exhaust blockage, ignition plug, internal fan-wheel gap. 4) Ignition normal but fault persists: housing temperature sensor contact.
Not stated
E-10LCD, E-2 … E-10Vevor CY-5001/5002/5004, 5-key and 3-key LCD panels
Manual
Unsuccessful startup
Manual's remedy: 1) Casing too hot and not cooled after 3 minutes of start-up. 2) Lots of white smoke in exhaust: check the filter screen next to the ignition plug (clean/replace), whether the pump sprays fuel forcefully, whether the ignition plug is aged. 3) Little or no white smoke: check for fuel shortage, frozen or blocked fuel circuit, pump stuck/damaged, combustion intake and exhaust clear, ignition plug damaged, inner fan-wheel clearance too large. 4) Ignites normally but still reports ignition failure: check the casing temperature sensor is in full contact with the casing, its pressure spring, and the sensor itself.
Casing not cooled after 3 minutes of start-up (cause 1)
E8Rotary-switch LCD, E0 … E15Heatport H2 / H4 (EnControl)
Manual
Blower motor
Manual's remedy: Check heating air intake for obstructions and that the blower turns freely; impeller damage (obstruction, over-torqued ducting clamp, debris under the heater) - replace blower; short circuit - check resistance and wiring; loose ECU casing / mispositioned magnetic sensor - fix ECU position; ECU.
Speed failure: motor speed off specification by more than 10% for longer than 30 seconds
E8Rotary-switch LCD, E0 … E15T4 two-knob LCD switch
Manual
Motor
Manual's remedy: Fix/reinstall the fan blade if stuck; replace the motor if defective; check the Hall sensor or circuit board; ensure motor wires are connected to the board socket.
Not stated
E10Rotary-switch LCD, E0 … E15Heatport H2 / H4 (EnControl)
Manual
Overheat: excess temperature measured at the overheat sensor
Manual's remedy: Check fan not blocked/damaged; check ducting free from obstruction; remove the PT1000 sensor, check connections/wiring and reinstall; replace sensor if wiring damaged; ECU.
Not stated
E10Rotary-switch LCD, E0 … E15T4 two-knob LCD switch
Manual
Overheat
Manual's remedy: Verify the air duct is not blocked; address temperature sensor failure or loose contact with the aluminium heat exchanger ('radiator').
Not stated
E-08Knob LCD (Hcalory HC-A01)Hcalory HC-A01
Manual
Ignition plug abnormality
Manual's remedy: Check the ignition plug connection; faulty plug - replace; main board failure - replace.
Not stated
E-10Knob LCD (Hcalory HC-A01)Hcalory HC-A01
Manual
Furnace temperature sensor abnormal
Manual's remedy: Check the furnace temperature sensor connector for a loose connection; incorrect or faulty sensor type - replace; main board failure - replace.
Not stated
E-08B2010 (spanner button)B2010 controller
Manual
Flame failure
Manual's remedy: Check for air or wax blockage in the fuel circuit causing poor fuel supply.
Not stated
E-10B2010 (spanner button)B2010 controller
Manual
Ignition failure (after two failed ignition attempts)
Manual's remedy: Check for blocked fuel circuit, poor fuel intake, stuck fuel pump, or blocked 'volatile net' (burner screen) due to fuel problems.
Two failed ignitions

Why does my diesel heater soot up?

Owners traced soot to four things.

  • Long running on a low setting. One owner had two identical heaters in identical garages: the one run mostly on minimum sooted up, the other did not. Owners One owner filled a new heater’s chamber with loose carbon in a few weeks of 15 to 20 minute runs at low heat. Owners
  • A rich mixture. One owner of a 2 kW unit found it set up with large-heater pump and fan values; changing them in the settings menu stopped the soot. Owners One owner cleaned a heater three times before getting the pump settings right. Owners Two owners cured rapid sooting by fitting a different fuel pump. Owners One owner with the tank 2 to 3 ft above the heater ended daily sooting by moving the tank level with the heater. Owners
  • Altitude. One owner’s heater was full of soot after 14 hours on low above 6,000 ft. Owners The Vevor CY manual’s plateau mode exists for this: it changes the air to fuel ratio for thin air. Manual See altitude tuning.
  • A restricted intake or exhaust. One owner had routed the exhaust through a coil; with the coil removed the sooting stopped. Owners The Dieselheat guide sends you to the air inlet and exhaust for partial blockage when a heater smokes all the time. Manual

Cutting the power can add to it. Gasmate’s manual says not to cut power during start-up or shut-down: it causes smoke at the next start, and repeated cuts cause carbon build-up. Manual

What are the signs of soot build-up?

  • The heater gradually loses heat and gets harder to start. Owners
  • White smoke appears after a period of running. The Vevor CY manual reads that as a clogged atomising screen at the glow plug. Manual
  • Black smoke appears after a period of use or in the second year. The Vevor CY manual reads that as carbon in the combustion chamber. Manual
  • The heater ends on a flame-out or failed-start code. Which number that is depends on the controller: see the table above.

How long should the high-power clean burn be?

The documents do not agree, so here is each one.

Document What it says
Belief rotary control guide High power for around 15 to 20 minutes every 6 to 8 hours
Dieselheat portable guide High power for around 15 min every 5 to 6 hours; it suggests about 15 min on high each time the heater is turned on
OnTrack manual 10 minutes at full heat and fan speed, monthly

All three rows are from manuals. Manual They were written for different heaters. Use the one for your own heater if you have it.

Two documents also cover a heater that is already smoking:

  • Dieselheat’s portable guide: for excessive smoke after long low-power running, run 2 hours on full power. Manual
  • Dieselheat’s fault-finding guide: if it still smokes after 15 min on full power, with the air inlet and exhaust checked, it needs a service. Manual

Does the clean burn actually work?

Seven owners in five threads describe running on high to keep soot down, six as a habit and one as a one-off cure, and none of them reports soot trouble since. Owners Their routines differ:

  • 15 to 20 minutes on high before packing up.
  • Starting on full power, and 15 minutes on full before switching off: second winter, never opened.
  • A couple of minutes on high before shutdown, together with a pump setting lowered for altitude.
  • A blast on high before switching off.
  • A burn at maximum at the end of each season: found clean when opened after two seasons.
  • Occasional 5-minute full-power runs in six months of full-time use. This owner is unsure the runs matter.
  • A couple of hours on high once, after which a heater that had not been firing first try started first time.

The limits of this evidence: nobody measured anything. These are habits and a few before and after cases, and three of these owners changed something else as well (a pump setting or the fuel). A high-power run also does not fix a cause that is still there. The owners with wrong pump values, an oversupplying pump or a restricted exhaust had to fix those.

What should I check, and in what order?

  1. Intake and exhaust. With the heater off and cold, check both pipes for partial blockage. Dieselheat’s guide makes this the first check for constant smoke. Manual
  2. Run it on high. Use the interval from your own manual, or one of those in the table. If it still smokes after the time your document gives, go on.
  3. Altitude. If you are well above sea level, switch on the plateau or Alpine mode if the panel has one: see altitude tuning.
  4. Pump and fan values. On a panel with a PIN menu, compare the values with what the heater came with. Write the originals down before changing anything: see the hidden settings menu.
  5. Tank height and pump. If the tank sits well above the heater, try it level with the heater, as one owner did. Owners If sooting returns within days of a clean, suspect the fuel pump, as two owners found. Owners
  6. Glow plug screen. A clogged screen is the next stop: see cleaning the glow plug and its screen.

When does the burn chamber need cleaning?

When the cheaper checks make no difference and the heater still only smokes or will not light. Two owners got their heaters running by emptying carbon out of the burn chamber: for one a new glow plug and screen had changed nothing, for the other a new pump and fuel lines. Owners A third burnt carbon out of the chamber and exhaust but changed other things at the same time and is not sure which step worked. A fourth found the chamber burnt out inside and replaced it. Owners The Vevor CY manual’s answer to carbon in the chamber is to remove the shell, the main board, the fan assembly and the combustion chamber, and fit a new chamber. Manual

Opening the chamber means new gaskets and careful reassembly of a part that carries exhaust gas.

If you are not sure, ask a technician. Opening the combustion chamber goes beyond routine owner maintenance. A mistake here can cause a fuel or exhaust leak. Stop if anything is unclear.

Related questions

Can I run a diesel heater on low all the time?
Owners disagree. One owner with two identical heaters in identical garages found that the one mostly run on minimum sooted up and the other did not. Another owner reports six months of full-time use at 1.6 Hz or lower with only occasional 5-minute full-power runs and no problems. The Belief and Dieselheat guides both tell you to run at high power regularly.
How long should the clean burn be?
The documents differ. Belief's rotary guide says around 15 to 20 minutes every 6 to 8 hours. Dieselheat's portable guide says around 15 min every 5 to 6 hours. OnTrack's manual says 10 minutes at full heat once a month. Follow the document for your own heater if you have one.
Will a run on high clean a heater that is already sooted?
Sometimes. One owner whose heater was not firing first try ran it on high for a couple of hours and it has started first time since. Dieselheat's portable guide gives 2 hours on full power for excessive smoke after long low-power running. Two owners whose heaters would no longer run had to empty carbon out of the burn chamber, and a third did so along with other changes.
Does kerosene stop soot?
Two owners report little or no soot with kerosene added to the diesel, one at 10 to 20% and one at about 1.5 L per tank. Nobody measured it, and the second also burns the chamber out at maximum at the end of each season. Only use a fuel your heater's manual allows.

Sources

Everything on this page is compiled from the documents and discussions below. We summarise them in our own words; follow the links for the originals.

  1. Belief diesel air heater user guide, rotary control (PDF) (dieselheat.com.au)
  2. Dieselheat portable heater user guide (PDF) (dieselheat.com.au)
  3. Dieselheat: diesel air heater fault finding guide (PDF) (dieselheat.com.au)
  4. OnTrack Outdoor: diesel heater instructions manual, updated (PDF) (cdn.shopify.com)
  5. Vevor diesel heater manual, CY-5001 / CY-5002 / CY-5004 (PDF copy) (xlrzbfnheqpszgtyhdkh.supabase.co)
  6. Gasmate portable diesel heater manual, DH203 (PDF) (snowys.com.au)
  7. Owner reports: full-power runs, kerosene, two identical heaters, exhaust coil removed (drive2.ru comments) (drive2.ru)
  8. Owner report: diesel diluted with kerosene, soot now minimal (drive2.ru comments) (drive2.ru)
  9. Owner report: 15 to 20 minutes on high before packing up (GoFastCampers forum) (forum.gofastcampers.com)
  10. Owner report: cleaned three times before the pump settings were right (GoFastCampers forum) (forum.gofastcampers.com)
  11. Owner report: a couple of hours on high restored first-time starts (GoFastCampers forum) (forum.gofastcampers.com)
  12. Owner report: full of soot after 14 hours on low above 6,000 ft (Expedition Portal forum) (forum.expeditionportal.com)
  13. Owner report: pump setting cut for altitude, high run before shutdown (Expedition Portal forum) (forum.expeditionportal.com)
  14. Owner report: six months at 1.6 Hz or lower with occasional full-power runs (Expedition Portal forum) (forum.expeditionportal.com)
  15. Owner report: lower minimum pump rate, blast on high before switching off (The Grey Nomads forum) (thegreynomads.activeboard.com)
  16. Owner report: 2 kW heater shipped with large-heater values (Reddit r/dieselheater) (reddit.com)
  17. Owner report: a different fuel pump ended the carbon overload (Reddit r/dieselheater) (reddit.com)
  18. Owner report: two-week-old heater packed with carbon, cured by a pump from an older heater (Reddit r/dieselheater) (reddit.com)
  19. Owner report: carbon burnt out of chamber and exhaust along with other changes (Reddit r/dieselheater) (reddit.com)
  20. Owner report: E-10 and smoke, burn chamber destroyed inside (Reddit r/dieselheater) (reddit.com)
  21. Owner report: daily sooting ended by moving the tank level with the heater (Reddit r/dieselheater) (reddit.com)
  22. Owner report: chamber full of loose carbon after short low-heat runs (Reddit r/vandwellers) (reddit.com)
  23. Owner report: E-08 cleared by cleaning carbon out of the chamber (Reddit r/dieselheater) (reddit.com)